Power Wire Copper Flexible PVC Insulated Electrical/Electric Power Wire Cable

Model NO.: power wire
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE, RoHS
Model: YJV
Brand: Hanli
Trademark: hanli
Transport Package: 100m
Specification: 30x30x6cm
Origin: Zhejiang
Model NO.: power wire
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE, RoHS
Model: YJV
Brand: Hanli
Trademark: hanli
Transport Package: 100m
Specification: 30x30x6cm
Origin: Zhejiang
Copper Flexible PVC Insulated Electrical/Electric Power Wire Cable

450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004
Harmonized Code
Designation H07V-K
Single Core PVC Insulated 
Size of conductor Nominal thickness of insulation


mm
Mean overall diameter

Upper limit

mm
Approx. Net weight per km



Kg
Nominal
Cross-sectional area

mm2
Number and diameter of wires
No. /mm
1.0 32/0.20 0.6 3.0 16
1.5 30/0.25 0.7 3.5 21
2.5 50/0.25 0.8 4.2 33
4 56/0.30 0.8 4.8 50
6 84/0.30 0.8 6.3 70
10 80/0.40 1.0 7.6 120
16 126/0.40 1.0 8.8 175
25 196/0.40 1.2 11.0 290
35 276/0.40 1.2 12.5 400
50 396/0.40 1.4 14.5 565
70 360/0.50 1.4 17.0 770
95 475/0.50 1.6 19.0 1010
120 608/0.50 1.6 21.0 1260
150 756/0.50 1.8 23.5 1580
185 925/0.50 2.0 26.0 1900
240 1221/0.50 2.2 29.5 2500

Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. 
2. Colors of standard: Red, black, brown, grey, orange, white, violet, pink, green/yellow, yellow


300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6181y
Single Core PVC Insulated and PVC Sheathed 
Size of conductor Nominal thickness of insulation


mm
Nominal thickness of
Sheath


mm
Mean overall diameter Approx. Net weight per km




Kg
Nominal
Cross-sectional area
mm2
Number and diameter of wires
mm
Lower limit

mm
Upper limit

mm
1.0 1/1.13 0.6 0.8 3.8 4.5 28
1.5 1/1.38 0.7 0.8 4.2 4.9 35
2.5 1/1.78 0.8 0.8 4.8 5.8 50
4 7/0.85 0.8 0.9 5.4 6.8 75
6 7/1.04 0.8 0.9 6.0 7.4 100
10 7/1.35 1.0 0.9 7.2 8.8 155
16 7/1.70 1.0 1.0 8.4 10.5 225
25 7/2.14 1.2 1.1 10.0 12.5 340
35 19/1.53 1.2 1.1 11.0 13.5 445

Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound. 
2. Core colors: Red, black. Sheath colour: Grey or white. 

Reference No 6192y
Flat Twin 
Size of conductor Nominal thickness of insulation


mm
Nominal thickness of
Sheath


mm
Mean overall
Dimensions
Approx. Net weight per km



Kg
Nominal
Cross-sectional area

mm2
Number and diameter of wires
mm
Lower limit


mm
Upper limit


mm
1.0 1/1.13 0.6 0.9 4.0*6.2 4.7*7.4 55
1.5 1/1.38 0.7 0.9 4.4*7.0 5.4*8.4 70
2.5 1/1.78 0.8 1.0 5.2*8.4 6.2*9.8 105
4 7/0.85 0.8 1.0 5.6*9.6 7.2*11.5 150
6 7/1.04 0.8 1.1 6.4*10.5 8.0*13.0 205
10 7/1.35 1.0 1.2 7.8*13.0 9.6*16.0 325
16 7/1.70 1.0 1.3 9.0*15.5 11.0*18.5 465

Notes
1. Conductor of high conductivity copper, wires insulated with PVC compound. Sheathed with PVC compound. 
2. Color of sheath: Grey or white, 


300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6193y
Three Core (Flat) 
Size of conductor Nominal
Thickness of insulation


mm
Nominal thickness of
Sheath


mm
Mean overall diameter Approx. Net weight per km



Kg
Nominal
Cross-sectional area

mm2
Number and diameter of wires
mm
Lower limit


mm
Upper limit


mm
1.0 1/1.13 0.6 0.9 4.0*8.4 4.7*9.8 77
1.5 1/1.38 0.7 0.9 4.4*9.8 5.4*11.5 100
2.5 1/1.78 0.8 1.0 5.2*11.5 6.2*13.5 150
4 7/0.85 0.8 1.1 5.8*13.5 7.4*16.5 230
6 7/1.04 0.8 1.1 6.4*15.0 8.0*18.0 300
10 7/1.35 1.0 1.2 7.8*19.0 9.6*22.5 485
16 7/1.70 1.0 1.3 9.0*22.0 11.0*26.5 700


Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound. 
2. Core colors: Green/ yellow blue and brown. Sheathed colors: Grey, white or black. 


Power Wire Copper Flexible PVC Insulated Electrical/Electric Power Wire Cable



Notes: 
Conductors of high conductivity copper wires, insulated with PVC compound, two cores twisted together.  Copper Flexible PVC Insulated Electrical/Electric Power Wire Cable

450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004
Harmonized Code
Designation H07V-K
Single Core PVC Insulated 
Size of conductor Nominal thickness of insulation


mm
Mean overall diameter

Upper limit

mm
Approx. Net weight per km



Kg
Nominal
Cross-sectional area

mm2
Number and diameter of wires
No. /mm
1.0 32/0.20 0.6 3.0 16
1.5 30/0.25 0.7 3.5 21
2.5 50/0.25 0.8 4.2 33
4 56/0.30 0.8 4.8 50
6 84/0.30 0.8 6.3 70
10 80/0.40 1.0 7.6 120
16 126/0.40 1.0 8.8 175
25 196/0.40 1.2 11.0 290
35 276/0.40 1.2 12.5 400
50 396/0.40 1.4 14.5 565
70 360/0.50 1.4 17.0 770
95 475/0.50 1.6 19.0 1010
120 608/0.50 1.6 21.0 1260
150 756/0.50 1.8 23.5 1580
185 925/0.50 2.0 26.0 1900
240 1221/0.50 2.2 29.5 2500

Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. 
2. Colors of standard: Red, black, brown, grey, orange, white, violet, pink, green/yellow, yellow


300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6181y
Single Core PVC Insulated and PVC Sheathed 
Size of conductor Nominal thickness of insulation


mm
Nominal thickness of
Sheath


mm
Mean overall diameter Approx. Net weight per km




Kg
Nominal
Cross-sectional area
mm2
Number and diameter of wires
mm
Lower limit

mm
Upper limit

mm
1.0 1/1.13 0.6 0.8 3.8 4.5 28
1.5 1/1.38 0.7 0.8 4.2 4.9 35
2.5 1/1.78 0.8 0.8 4.8 5.8 50
4 7/0.85 0.8 0.9 5.4 6.8 75
6 7/1.04 0.8 0.9 6.0 7.4 100
10 7/1.35 1.0 0.9 7.2 8.8 155
16 7/1.70 1.0 1.0 8.4 10.5 225
25 7/2.14 1.2 1.1 10.0 12.5 340
35 19/1.53 1.2 1.1 11.0 13.5 445

Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound. 
2. Core colors: Red, black. Sheath colour: Grey or white. 

Reference No 6192y
Flat Twin 
Size of conductor Nominal thickness of insulation


mm
Nominal thickness of
Sheath


mm
Mean overall
Dimensions
Approx. Net weight per km



Kg
Nominal
Cross-sectional area

mm2
Number and diameter of wires
mm
Lower limit


mm
Upper limit


mm
1.0 1/1.13 0.6 0.9 4.0*6.2 4.7*7.4 55
1.5 1/1.38 0.7 0.9 4.4*7.0 5.4*8.4 70
2.5 1/1.78 0.8 1.0 5.2*8.4 6.2*9.8 105
4 7/0.85 0.8 1.0 5.6*9.6 7.2*11.5 150
6 7/1.04 0.8 1.1 6.4*10.5 8.0*13.0 205
10 7/1.35 1.0 1.2 7.8*13.0 9.6*16.0 325
16 7/1.70 1.0 1.3 9.0*15.5 11.0*18.5 465

Notes
1. Conductor of high conductivity copper, wires insulated with PVC compound. Sheathed with PVC compound. 
2. Color of sheath: Grey or white, 


300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6193y
Three Core (Flat) 
Size of conductor Nominal
Thickness of insulation


mm
Nominal thickness of
Sheath


mm
Mean overall diameter Approx. Net weight per km



Kg
Nominal
Cross-sectional area

mm2
Number and diameter of wires
mm
Lower limit


mm
Upper limit


mm
1.0 1/1.13 0.6 0.9 4.0*8.4 4.7*9.8 77
1.5 1/1.38 0.7 0.9 4.4*9.8 5.4*11.5 100
2.5 1/1.78 0.8 1.0 5.2*11.5 6.2*13.5 150
4 7/0.85 0.8 1.1 5.8*13.5 7.4*16.5 230
6 7/1.04 0.8 1.1 6.4*15.0 8.0*18.0 300
10 7/1.35 1.0 1.2 7.8*19.0 9.6*22.5 485
16 7/1.70 1.0 1.3 9.0*22.0 11.0*26.5 700


Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound. 
2. Core colors: Green/ yellow blue and brown. Sheathed colors: Grey, white or black. 


Power Wire Copper Flexible PVC Insulated Electrical/Electric Power Wire Cable



Notes: 
Conductors of high conductivity copper wires, insulated with PVC compound, two cores twisted together. 

LCD Module

According to the different backlight sources, LCDs can be divided into two types: CCFL displays and LED displays.
Misunderstanding:
Many users believe that liquid crystal displays can be divided into LEDs and LCDs. To some extent, this understanding is misguided by advertisements.

The LED display on the market is not a true LED display. To be precise, it is an LED-backlit Liquid Crystal Display. The liquid crystal panel is still a traditional LCD display. In a sense, this is somewhat fraudulent. nature! South Korea`s Samsung was once convicted by the British Advertising Association as violating the country`s advertising laws because its [LEDTV" LCD TVs were suspected of misleading consumers. For liquid crystal displays, the most important key is its LCD panel and backlight type, while the LCD panels of displays on the market generally use TFT panels, which are the same. The difference between LEDs and LCDs is only their backlight types: LED The backlight and CCFL backlight (that is, fluorescent lamps) are diodes and cold cathode lamps, respectively.

LCD is the acronym for Liquid Crystal Display, which means "liquid crystal display", that is, liquid crystal display. The LED display refers to a type of liquid crystal display (LCD), that is, a liquid crystal display (LCD) with LED (light emitting diode) as the backlight source. It can be seen that LCD includes LEDs. Corresponding to the LED display is actually a CCFL display.

(1) CCFL
Refers to a liquid crystal display (LCD) with CCFL (cold cathode fluorescent lamp) as the backlight source.
The advantage of CCFL display is good color performance, but the disadvantage is higher power consumption.

(2) LED
Refers to a liquid crystal display (LCD) that uses LEDs (light emitting diodes) as a backlight source, and generally refers to WLEDs (white light LEDs).
The advantages of LED displays are small size and low power consumption. Therefore, using LEDs as a backlight source can achieve high brightness while taking into account lightness and thinness. The main disadvantage is that the color performance is worse than that of CCFL monitors, so most professional graphics LCDs still use traditional CCFL as the backlight source.

Lcd Module,Kortek Tft Lcd Monitor,Game Boy Color Tft Lcd Kit,A-Si Active Matrix Tft Lcd

ESEN Optoelectronics Technology Co., Ltd, , https://www.esenoptoelectronics.com

This entry was posted in on