Countermeasure: Please check if each instruction in the program is used correctly.
Error Number (D8065): 6503
Error message: SYNTAXERROR (plc stops running, grammar error)
Error content: OUTT, there is no set value after OUTC, and the number of operands of the application instruction is insufficient. Countermeasure: Please check whether the usage of each instruction in the program is correct.
Error Number (D8065): 6504
Error message: SYNTAXERROR (PLC stopped running, grammar error)
Error content: Repeat the use of the number of P, interrupt the insertion of the input number and repeat the use of the high-speed counter input number. Countermeasure: Please check whether the usage of each instruction in the program is correct.
Error number (D8065): 6505
Error message: SYNTAXERROR (PLC stopped running, grammar error)
Error content: The specified component is out of range. Countermeasure: Please check if each instruction in the program is used correctly.
Error Number (D8065): 6506
Error message: SYNTAXERROR (PLC stopped running, grammar error)
Error content: Use undefined instruction countermeasures: Please check if each instruction in the program is used correctly.
Error Number (D8065): 6507
Error message: SYNTAXERROR (PLC stopped running, grammar error)
Error content: P number error countermeasure: Please check whether the usage of each instruction in the program is correct.
Error number (D8065): 6508
Error message: SYNTAXERROR (PLC stopped running, grammar error)
Error content: I number error countermeasure: Please check whether the usage of each instruction in the program is correct.
Error Number (D8065): 6509
Error message: SYNTAXERROR (PLC stopped running, grammar error)
Error content: Other countermeasures: Please check if each instruction in the program is used correctly.
Mitsubishi FX series PLC error number (D8065): 6510
Error message: SYNTAXERROR (PLC stopped running, grammar error)
Error content: Improper use of the N number of the MC/MCR: Please check if the usage of each instruction in the program is correct.
Error Number (D8065): 6511
Error message: SYNTAXERROR (PLC stopped running, grammar error)
Error content interrupt Insertion input number and high-speed counter input number repeated use countermeasures: Please check whether the usage of each instruction in the program is correct.