HUAWEI WATCH2 Bluetooth Edition Quick Unpacking + Half-day Use Experience

HUAWEI WATCH 2 Huawei's second-generation smart sports watch Bluetooth version Bluetooth call GPS heart rate FIRSTBEAT sports guide NFC payment carbon crystal black 1688 yuan The second generation of Huawei Watch weight 57g, the main material is plastic. A 1.2-inch diameter AMOLED screen with a resolution of 390x390 and IP68 rated dust and water resistance. The two physical buttons on the right side are at 2 o'clock and 4 o'clock respectively. Compared to the first-generation Huawei Watch, the second-generation products have to be more "sporty". It has built-in Wi-Fi, Bluetooth, N Jingdong direct links to encyclopedias.


Not much nonsense, come out and figure it out

The back of the packet

It is just a layer of film

Like a cake?

True positive

True back

The same lunch box packaging, with the cover below can automatically slide down. .

Dangdang Dangdang!

Translation: Our packaging is absolutely not anti-human

Put the table aside

Accessories box

Pull out

All accessories, adapters, chargers, manuals...

A few drawings


Android wear Chinese version, long absence google icon.

The end of the overall out of the box, talk about playing + use about five hours of personal experience.

Advantage/feel

Excellent workmanship, sports winds, good fortune, and I’ve been with Leroy for several years now.

Android smart table operating logic are not bad, are the android waer operating system, huawei watch2 and I used Ticwtach2 compared to the system is more smooth, but the screen is a bit smaller than tic2.

Although it is IP68, the instructions do not recommend swimming or bathing.

The dial is Corning Gorilla 3 generations, recommended film

Ios support is not good, Andrews will not say

JD's pre-sale is to send individual fats. It's not bad, but it's still under APP. .


Because the Android table system is similar, the workmanship and appearance become the most important selection parameters. If the perfect score is ten, I give Huawei 9 points.



Shortcomings

I have only found one disadvantage in the past. That is, Huawei's watch2 mobile app designers have flooded their brains. Not that they are not good, but they use different APPs for different functions. The content is not integrated. Just put the table will let you down the Android wear app, if you want more features, it will prompt you to "Huawei wear APP." But wtach2, the main sport, doesn't have sports support under "Huawei wear APP", so you have to get "Sports Health APP". If you want to download more software, you have to download "Huawei Application Market APP". PS: Huawei's own software, if you are not a Huawei mobile phone, you must also install the "Huawei Mobile Services" component. If you want to use huawei pay, you also need to install the "CUP Wearable Device Security Control" component.

Surge Protection Device SPD

Product Description


SPD Surge Protective Device,Lightning Surge Protector
Surge Protection Device (SPD)


It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.

Surge protective Device Model Selection

With the impact of international information flow, the rapid development of microelectronic science and technology, communication, computer and automatic control technology, make the building start to go for high quality, high functional area, formed a new building style-intelligent building. As inside the intelligent building there are lot of information system, <<Building lightning protection design norm>> GB50057-94(2002 vision)(hereafter brief as <<lightning protection norm>>) put forward the relative requirement to install the surge protective device, to ensure the information system safely and stable running.
SPD essentially is a equipotential connection material, its model selection is according to the different lightning protection area, different lightning electromagnetic pulse critical and different equipotential connection position, decide which kind of SPD used in the area, to achieve the equipotential connection with the common earth electrode. Our statement will based on SPD's maximum discharge current Imax, continuous operating voltage Uc, protection voltage Up, alarm mode etc.
As per << Lightning Protection Norm>> item 6.4.4 stipulation "SPD must can withstand the expected lightning current flow and should confirm to the additional two requirements: the maximum clamp voltage during surge across, capable to extinguish the power frequency follow-on current after lightning current across." That is the value of SPD's max. clamp voltage add its induction voltage of two ends should be same with the system's basic insulation level and the equipment allowed max. surge voltage.

SPD for Power Supply System Series Selection Guide

The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.
The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose.
SPD for power supply system specification selection principle
Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage.
TT System: Uc≥1.55Uo (Uo is low voltage system to null line voltage)
TN System: Uc≥1.15Uo
IT System: Uc≥1.15Uo(Uo is low voltage system to line voltage)
Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment
Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.
SP1 Series

Normal Working Conditions
-Altitude not exceed 2000m
-Ambient air temperature:
Normal range: -5ºC~+40ºC
Extend range: -40ºC~+80ºC
-Relative Humidity: 30% - 90% under indoor temperature condition
- At the place without obviously shaking and shock vibration
- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust)

Classification

-As per Nominal Discharge Current:
5,10,20,30,40,60KA(8/20µs)
- As per Maximum continuous operating voltage:
275V,320V,385V,420V,440V,460V
- As per to poles
1P,1P+N,2P,3P,3P+N,4P
- As per auxiliary functions:
a. With remote signal output ( remote alarm function)
b. Without remote signal output

Selection Principle

- The continuous applied voltage on the two terminals of SPD should not more than the maximum continuous operating voltage Uc value;
- The voltage protection level Up of SPD should less than the maximum impulse withstand voltage of the protected equipment;
- As per to the different earthing system and protection mode to select the specification accordingly;

Product Features

1, built-in over-current overheating, temperature control circuit technology.

2, the module design, easy installation, online replacement.

3, low leakage current, fast response time, low residual voltage.

4, alarm indication device, green (normal) v red (fault).

Model/Technical Parameters WR-B60 WR-B80 WR-B100 WR-B120 WR-B150
Rated Operating Voltage Un (V ~) 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V
Maximum Continuous Operating Voltage Uc (V ~) kV 385V 420V 385V 420V 385V 420V 385V 420V 385V 420V
Voltage Protection Level Up (V ~) kV ≤1.8≤2.2 ≤2.4≤2.5 ≤2.5≤3.2 ≤3.4≤3.7 ≤4.0≤4.5

Maximum Discharge

Current Imax(8/μ20μs)kA

60 80 100 120 150

Nominal Discharge

Current In(8/μ20μs)kA

30 40 60 80 100
Response Time <25 <100
L/N(mm²)The Cross Section Of L/N Line 16,25 16,25 16,25 16,25 25,35
PE (mm²)The Cross Section Of PE Line 16,25 25,35 25,35 25,35 35
Fuse or Switch (A) 63A 63A 63A,100A 63A,100A 63A,125A
The Line Section of Communication and Alarm (mm²) ≥ 1.5

Operating

Environment-C

(-40ºC~-+85ºC)
Relative humidity 25 ºC ≤95%
installation Standard Rail35mm
Material of Outer Covering Fiber Glass Reinforced Plastic

Surge Protector SPD,Surge Protection Device SPD,SPD

Wenzhou Korlen Electric Appliances Co., Ltd. , https://www.zjaccontactor.com

This entry was posted in on