0.6/1KV Overhead Aluminum Cable Quadruplex ACSR Neutral Conductor
Â
Applications of quadruplex abc cableÂ
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service
for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceedÂ
75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
Â
Specification of quadruplex abc cable
 CONSTRUCTION of ABC Cable
(1)  Conductor :
 a) Phase-
The phase conductors shall be of H68 Condition aluminum conductor and compacted circular stranded.
 b) Neutral or messenger-
 The neutral or messenger conductor shall be of aluminum alloy conductor and compacted circular stranded.
 c) Street-Lighting-
 The street lighting conductors shall be of H68 Condition aluminum conductor and compacted circular stranded.
(2)  Insulation :
The phase,neutral and street lighting conductors shall be extruded with Polyethylene (PE) or Cross-linked Polyethylene (XLPE) as insulation.
(3)Â Â Assembly
    The cable consists of insulated phase and street lighting aluminum conductors, shall be held firmly onto the
 insulated neutral messenger aluminum alloy conductor in a right hand (Z) lay.
Spec mm2 |
   Conductor structure |
Insulation Material |
Insulation Thickness (mm) |
Approx overall diameter (mm) |
Approx weight (kg/km) |
|
 | Phase |
Neutral (alloy) |
 |  |  |  |
 | No./mm |
No./mm |
 |  |  |  |
1*16+1*16 |
7/1.72 |
7/1.72 |
XLPE (HDPE) |
1.2 |
12.5 |
110.1 |
1*25+1*25 |
7/2.15 |
7/2.15 |
 | 1.2 |
14.9 |
163.9 |
1*35+1*35 |
7/2.54 |
7/2.54 |
 | 1.4 |
17.5 |
229.0 |
1*50+1*50 |
7/2.92 |
7/2.92 |
 | 1.4 |
20.1 |
300.0 |
1*70+1*70 |
19/2.15 |
19/2.15 |
 | 1.4 |
23.6 |
423.2 |
1*95+1*95 |
19/2.54 |
19/2.54 |
 | 1.6 |
27.6 |
585.4 |
2*16+1*16 |
7/1.72 |
7/1.72 |
 | 1.2 |
14.2 |
175.8 |
2*25+1*25 |
7/2.15 |
7/2.15 |
 | 1.2 |
16.7 |
258.4 |
2*35+1*35 |
7/2.54 |
7/2.54 |
 | 1.4 |
19.7 |
361.2 |
2*50+1*50 |
7/2.92 |
7/2.92 |
 | 1.4 |
22.5 |
472.1 |
2*70+1*70 |
19/2.15 |
19/2.15 |
 | 1.4 |
26.1 |
658.3 |
2*95+1*95 |
19/2.54 |
19/2.54 |
 | 1.6 |
30.5 |
908.2 |
3*16+1*16 |
7/1.72 |
7/1.72 |
 | 1.2 |
16.3 |
241.5 |
3*25+1*25 |
7/2.15 |
7/2.15 |
 | 1.2 |
19.1 |
353.6 |
3*35+1*35 |
7/2.54 |
7/2.54 |
 | 1.4 |
22.5 |
493.5 |
3*50+1*50 |
7/2.92 |
7/2.92 |
 | 1.4 |
25.7 |
644.1 |
3*70+1*70 |
19/2.15 |
19/2.15 |
 | 1.4 |
29.7 |
895.2 |
3*95+1*95 |
19/2.54 |
19/2.54 |
 | 1.6 |
34.6 |
1233.0 |
Â
    0.6/1KV Overhead Aluminum Cable Quadruplex ACSR Neutral Conductor
Â
Applications of quadruplex abc cableÂ
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service
for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceedÂ
75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
Â
Specification of quadruplex abc cable
 CONSTRUCTION of ABC Cable
(1)  Conductor :
 a) Phase-
The phase conductors shall be of H68 Condition aluminum conductor and compacted circular stranded.
 b) Neutral or messenger-
 The neutral or messenger conductor shall be of aluminum alloy conductor and compacted circular stranded.
 c) Street-Lighting-
 The street lighting conductors shall be of H68 Condition aluminum conductor and compacted circular stranded.
(2)  Insulation :
The phase,neutral and street lighting conductors shall be extruded with Polyethylene (PE) or Cross-linked Polyethylene (XLPE) as insulation.
(3)Â Â Assembly
    The cable consists of insulated phase and street lighting aluminum conductors, shall be held firmly onto the
 insulated neutral messenger aluminum alloy conductor in a right hand (Z) lay.
Spec mm2 |
   Conductor structure |
Insulation Material |
Insulation Thickness (mm) |
Approx overall diameter (mm) |
Approx weight (kg/km) |
|
 | Phase |
Neutral (alloy) |
 |  |  |  |
 | No./mm |
No./mm |
 |  |  |  |
1*16+1*16 |
7/1.72 |
7/1.72 |
XLPE (HDPE) |
1.2 |
12.5 |
110.1 |
1*25+1*25 |
7/2.15 |
7/2.15 |
 | 1.2 |
14.9 |
163.9 |
1*35+1*35 |
7/2.54 |
7/2.54 |
 | 1.4 |
17.5 |
229.0 |
1*50+1*50 |
7/2.92 |
7/2.92 |
 | 1.4 |
20.1 |
300.0 |
1*70+1*70 |
19/2.15 |
19/2.15 |
 | 1.4 |
23.6 |
423.2 |
1*95+1*95 |
19/2.54 |
19/2.54 |
 | 1.6 |
27.6 |
585.4 |
2*16+1*16 |
7/1.72 |
7/1.72 |
 | 1.2 |
14.2 |
175.8 |
2*25+1*25 |
7/2.15 |
7/2.15 |
 | 1.2 |
16.7 |
258.4 |
2*35+1*35 |
7/2.54 |
7/2.54 |
 | 1.4 |
19.7 |
361.2 |
2*50+1*50 |
7/2.92 |
7/2.92 |
 | 1.4 |
22.5 |
472.1 |
2*70+1*70 |
19/2.15 |
19/2.15 |
 | 1.4 |
26.1 |
658.3 |
2*95+1*95 |
19/2.54 |
19/2.54 |
 | 1.6 |
30.5 |
908.2 |
3*16+1*16 |
7/1.72 |
7/1.72 |
 | 1.2 |
16.3 |
241.5 |
3*25+1*25 |
7/2.15 |
7/2.15 |
 | 1.2 |
19.1 |
353.6 |
3*35+1*35 |
7/2.54 |
7/2.54 |
 | 1.4 |
22.5 |
493.5 |
3*50+1*50 |
7/2.92 |
7/2.92 |
 | 1.4 |
25.7 |
644.1 |
3*70+1*70 |
19/2.15 |
19/2.15 |
 | 1.4 |
29.7 |
895.2 |
3*95+1*95 |
19/2.54 |
19/2.54 |
 | 1.6 |
34.6 |
1233.0 |
Â
For the 33kV Oil Immersed Power Transformer, we can produce capacity upto 50MVA. We use the best quality of raw material and advance design software to provide low noise, low losses, low partial discharge and high short-circuit impedance for power transformer.
Our power transformer are widely used in national grid, city grid, rural grid, power plant, industrial and mining enterprise, and petrochemical industry.
Conventer Transformer,33Kv Power Transformer,33Kv Power Transformer With Octc,Power Transformer With Octc
Hangzhou Qiantang River Electric Group Co., Ltd.(QRE) , https://www.qretransformer.com